Cessna 172S Frayed Aileron Cable During a routine inspection an aileron cable (p/n 0510105-364) was found shiny (worn) where it passes through the ceiling pulley cluster. When it was viewed 288
Frayed And Separated
During a routine inspection an aileron cable (p/n 0510105-364) was found shiny (worn) where it passes through the ceiling pulley cluster. When it was viewed through a strong magnifying glass, many broken strands could be seen.
Key Takeaways:
- Routine inspections uncovered diverse mechanical issues, including frayed aileron and rudder cables, and structural failures such as a cracked fuel tank and separated starter housing.
- Engine-related discrepancies included a leaking dipstick housing and cracked magneto rotor gears, with similar cracking observed even on new magneto components.
- The reported incidents underscore the critical role of thorough routine maintenance in identifying wear, chafing, and structural integrity issues across various aircraft systems.